Frequently Asked Questions (FAQ's)
|
Home : Frequently Asked Questions (FAQ's)
|
|
|
TECHNICAL QUESTIONS AND ANSWERS |
 |
| Q. |
What gauge wire should I use to run out to the power supply from the switch? |
| A. |
You should use 18 gauge wire.
|
| Q. |
What kind of wire should I use if the power supply is going to be placed in the fuselage? |
| A. |
You should use 18 gauge shielded cable.
|
| Q. |
What size breaker should I use for a (12v Single Flash) 152-0007? |
| A. |
If the power supply is wired separately you should use a 2 amp breaker.
If the power supply is wired together (with the other wing) you should use a 5 amp breaker.
|
| Q. |
What size breaker should I use for a (24v Single Flash) 152-0010? |
| A. |
If the power supply is wired separately you should use a 1.5 amp breaker.
If the power supply is wired together 9with the other wing) you should use a 3 amp breaker.
|
| Q. |
What size breaker should I use for a (12v Double Flash) 152-0011? |
| A. |
If the power supply is wired separately you should use a 2.7 amp breaker.
If the power supply is wired together (with the other wing) you should use a 6 amp breaker.
|
| Q. |
Can you use a different lamp manufacturer with an Aeroflash power supply or vice versa? |
A.
|
We do not recommend this procedure as it may damage the lamp or power supply. |
| Q. |
Power supply charges but no light output, how do I check unit? |
| A. |
With a volt meter, take the ground lead (from the meter) to the ground (of the unit) and using the red lead (from meter) at pin #1 (on the 3 pin nylon connector) you should have a reading of 350v to 450v output, at pin #2 you should have a reading of 0v output and at pin #3 you should have a reading of 150v to 175v output.
|
| Q. |
Do I need a dummy load resistor to a beacon flasher? |
| A. |
This load resistor is needed for the single light load and also for the longevity of lamp and flasher. |
For more information or other questions, use our Contact Us page, or call 312-733-3513 Ext. 300 (6:00 AM to 2:30 PM Central Time).